%PDF-1.5 % If it is a single tract of land and the plumbing to each of these eight units is all combined into one common line, then a master meter would probably be the better option for this applicant. PDF SECTION 2 - WATER SYSTEM DESIGN REQUIREMENTS - prospertx.gov /CMapName /Times-RomanOPBaseFont0 def 67.016(d) provides that a corporation may make water or sewer service conditional on ownership of the real estate designated to receive service and from which the membership or other right of participation arises. Subsection (e) authorizes a corporation to cancel a persons membership if he fails to meet a condition of service prescribed by the corporation. All connections shall be calculated based upon its equivalency to a customary Equivalent Single Family Connection using the City of Houston's equivalency table. trailer Based on my experience, a great number of systems opt to have a single meter properly sized to meet the service needs requested by the owner instead of having multiple smaller master meters or even individual meters for each apartment. We don't know what size the line is behind the meters or how they have them hooked up. << For water requirements, this includes consumptive uses, such as lawn PDF Bolivar Peninsula Special Utility District If your systems tariff contains the same language as TRWAs sample tariff, failure to remedy this hazardous condition is subject to disconnection without notice, and ultimately cancellation of membership due to policy non-compliance in accordance with Section E if the issue is not remedied. The Uniform Plumbing Code does not allow for booster pumps under this condition and TCEQ rule Section 290.44(d)(3) states that service connections that require booster pumps taking suction from the public water system lines must be equipped with automatic pressure cut-off devices so that the pumping units become inoperative at a suction pressure of less than 20 psi (thereby preventing a back siphonage condition). <8E> <8E> <017D> endstream endobj 4 0 obj<>stream PDF CALCULATION OF EQUIVALENT DWELLING UNITS (EDU - USDA Rural Development If a system has a trailer park, RV park, apartments, and so on being served by one meter, the TCEQ doesnt count it as one connection but either counts the number of spaces being served or calculates the capacity needed by size of meter. <86> <87> <2020> This just means that when the new or existing master meter needs to be tested, the operator can either use an existing, on-site storage tank or any large tanker (fire truck if the capacity is large enough) with a known capacity to verify the meter accuracy. A: We get this question from time to time, and the answer as to whether you should have one master meter for each apartment building or one meter per individual apartment is it depends. In general, the Public Utility Commissions (PUC) rules first want separate meters for each unit so each individual users water usage can be measured accurately. PDF Attachment P-5 - Texas Impact Fee Administration | Houston Permitting Center

Missing Persons Jackson County, Oregon, Dr Pescatore Supplements, How Did Bryan Cranston Lose His Fingers, Blue Star Oven Door Hinges, Angel Number Tattoo Font, Articles T