Circulation. When the heart rate increases to more than 100 bpm, PPV may be discontinued if there is effective respiratory effort.5 Oxygen is decreased and discontinued once the infant's oxygen saturation meets the targeted levels (Figure 1).5, If there is no heartbeat after 10 minutes of adequate resuscitative efforts, the team can cease further resuscitation.1,5,6 A member of the team should keep the family informed during the resuscitation process. Immediate, unlimited access to all AFP content, Immediate, unlimited access to this issue's content. A newly born infant in shock from blood loss may respond poorly to the initial resuscitative efforts of ventilation, chest compressions, and/or epinephrine. If the infant needs PPV, the recommended approach is to monitor the inflation pressure and to initiate PPV using a peak inspiratory pressure (PIP) of 20 cm H2O for the first few breaths; however, a PIP of 30 to 40 cm H2O (in some term infants) may be required at a rate of 40 to 60 breaths per minute.5,6 The best measure of adequate ventilation is prompt improvement in heart rate.24 Auscultation of the precordium is the primary means of assessing heart rate, but for infants requiring respiratory support, pulse oximetry is recommended.5,6 However, if the heart rate does not increase with mask PPV and there is no chest rise, ventilation should be optimized by implementing the following six steps: (1) adjust the mask to ensure a good seal; (2) reposition the airway by adjusting the position of the head; (3) suction the secretions in the mouth and nose; (4) open the mouth slightly and move the jaw forward; (5) increase the PIP enough to move the chest; and (6) consider an alternate airway (endotracheal intubation or laryngeal mask airway).5 PIP may be decreased when the heart rate increases to more than 60 bpm, and PPV may be discontinued once the heart rate is more than 100 bpm and there is spontaneous breathing. Breathing is stimulated by gently rubbing the infant's back. For term infants who do not require resuscitation at birth, it may be reasonable to delay cord clamping for longer than 30 seconds. If all these steps of resuscitation are effectively completed and there is no heart rate response by 20 minutes, redirection of care should be discussed with the team and family. Compared with term infants receiving early cord clamping, term infants receiving delayed cord clamping had increased hemoglobin concentration within the first 24 hours and increased ferritin concentration in the first 3 to 6 months in meta-analyses of 12 and 6 RCTs. Most newly born infants do not require immediate cord clamping or resuscitation and can be evaluated and monitored during skin-to-skin contact with their mothers after birth. Table 1 lists evidence and recommendations for interventions during neonatal resuscitation.1,2,57,2043, Intrapartum suctioning is not recommended with clear or meconium-stained amniotic fluid.1,2,5,6, Endotracheal suctioning of vigorous* infants is not recommended.1,2,5,6, Endotracheal suctioning of nonvigorous infants born through meconium-stained amniotic fluid may be useful.1,2,5, A self-inflating bag, flow-inflating bag, or T-piece device can be used to deliver positive pressure ventilation.1,6, Auscultation should be the primary means of assessing heart rate, and in infants needing respiratory support, the goal should be to check the heart rate by auscultation and by pulse oximetry.6, Initial PIP of 20 cm H2O may be effective, but a PIP of 30 to 40 cm H2O may be necessary in some infants to achieve or maintain a heart rate of more than 100 bpm.5, Ventilation rates of 40 to 60 breaths per minute are recommended.5,6, Use of an exhaled carbon dioxide detector in term and preterm infants is recommended to confirm endotracheal tube placement.5,6, Laryngeal mask airway should be considered if bag and mask ventilation is unsuccessful, and if endotracheal intubation is unsuccessful or not feasible.5,6, No evidence exists to support or refute the use of mask CPAP in term infants.2,5, PEEP should be used if suitable equipment is available, such as a flow-inflating bag or T-piece device.5, Delivery rooms should have a pulse oximeter readily available.57, A pulse oximeter is recommended when supplemental oxygen, positive pressure ventilation, or CPAP is used.57, Supplemental oxygen should be administered using an air/oxygen blender.57.

What Caused The Sharpeville Massacre, Steve Hermann Hotels Rancho Santa Fe, Carroll County Il Scanner, Articles N